Sign In | Join Free | My himfr.com
Home > Electronics Test Instruments >

HCTS0030A 200mV/A Ultra sensitive Flexible Current Probe for 50/60Hz Tiny Current

    Buy cheap HCTS0030A 200mV/A Ultra sensitive Flexible Current Probe for 50/60Hz Tiny Current from wholesalers
     
    Buy cheap HCTS0030A 200mV/A Ultra sensitive Flexible Current Probe for 50/60Hz Tiny Current from wholesalers
    • Buy cheap HCTS0030A 200mV/A Ultra sensitive Flexible Current Probe for 50/60Hz Tiny Current from wholesalers
    • Buy cheap HCTS0030A 200mV/A Ultra sensitive Flexible Current Probe for 50/60Hz Tiny Current from wholesalers

    HCTS0030A 200mV/A Ultra sensitive Flexible Current Probe for 50/60Hz Tiny Current

    Ask Lasest Price
    Brand Name : MEASTEK
    Model Number : HCTS0030A
    Payment Terms : T/T,Western Union,MoneyGram
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    HCTS0030A 200mV/A Ultra sensitive Flexible Current Probe for 50/60Hz Tiny Current

    HCTS0030A 200mV/A Ultra sensitive Flexible Current Probe for 50/60Hz Tiny Current


    Ultra-high sensitivity measurement

    The HCTS0030A flexible current probe has a sensitivity of up to 200mV/A, which can accurately capture tiny current changes and perform well in scenarios such as measuring 50/60Hz tiny currents.


    Wideband performance

    With a high-frequency bandwidth of 30MHz, it can effectively detect high-frequency sinusoidal current waveforms and meet a variety of high-frequency current measurement needs.


    Small package adaptation

    The outer diameter of the induction loop is only 1.6mm (1.7mm Max), and the withstand voltage value is 1KVpk, which is particularly suitable for current measurement of small package devices such as MOSFET, IGBT device pins (TO-220, TO-47 packages) and capacitor ripple current measurement.


    Low interference design

    The insertion loss is almost zero, only a few picohenries, and the interference to the measured object is minimal. The standard BNC output interface is convenient for connecting oscilloscopes and other equipment to observe current waveforms.


    Safe and convenient use

    USB 5V power supply, flexible to use. Follow the specifications during operation, such as ensuring that the BNC terminal is grounded and the measured wire passes through the center of the probe ring, to ensure measurement accuracy and safety.



    Specifications

    ModelHCTS0030A
    Sensitivity (mV/A)200
    PeakCurrent (KA)0.03

    dI/dt(KA/μs)

    2
    Maximum noise (mV Vpp)20
    Attenuation characteristics(%/ms)80
    Low frequency bandwidth -3dB(Hz)116
    High frequency bandwidth -3dB(MHz)30
    Typical accuracy

    2%

    Insulation voltage value

    1KV


    HCT(S)XXXXA Series Other Technical Parameters

    Maximum output voltage

    6Vpk

    Terminal load

    ≥100kΩ

    Power supply modeUSB 5V (standard adapter)
    Operating temperature rangeIntegrator

    0℃ - 50℃

    Probe ring

    0℃ - 100℃

    Storage temperature range

    -40℃~80℃


    Product Description

    HCTS0030A 200mV/A Ultra sensitive Flexible Current Probe for 50/60Hz Tiny Current

    (Take HCTS0120A as an example)


    1) Input interface: current probe test signal input terminal.
    2) Output interface: current probe integrator signal output terminal.
    3) USB 5V power supply interface: standard USB (type B) interface. (USB power supply cable and power adapter are standard)

    4) Test connection diagram.

    HCTS0030A 200mV/A Ultra sensitive Flexible Current Probe for 50/60Hz Tiny Current


    Mechanical specifications

    ModelHCTSXXXXA
    Typical value of flexible probe circumference (customizable)

    80mm

    Typical value of induction ring body diameter

    1.6mm

    Typical value of flexible probe diameter (customizable)

    25mm

    Induction loop connection cable length1 M (customizable)
    BNC connection cable length1 M or 2 M, 1 M is Standard

    Integrator body dimensions

    (including BN port dimensions)

    About 110(L)*47(W)*30(H)mm
    USB cable (AM-BM)About 1.8m
    USB output adapterAbout 59mm*30mm*20mm
    Probe weightAbout 150g
    Box weight (including probe)About 960g


    Care And Maintenance

    1) Keep the probe clean and dry.
    2) If cleaning is required, wipe with a soft dry cloth. Do not use chemical cleaning agents.
    3) When the probe is not in use, please put it in the packaging provided and place it in a cool, clean and dry place.
    4) When transporting the probe, be sure to put it in the packaging provided by our company to prevent shock.
    5) Do not pull the input and output lines hard to avoid excessive twisting, bending or knotting.


    Packing List

    NameQuantity
    Current probe integrator1 piece
    Current probe flexible induction coil1 piece
    USB output adapter (5V/1A)1 piece
    USB power cable1 piece
    BNC output cable1 piece
    Electronic manual1 serving


    Quality HCTS0030A 200mV/A Ultra sensitive Flexible Current Probe for 50/60Hz Tiny Current for sale