Sign In | Join Free | My himfr.com
Home > Electronics Test Instruments >

HCTS0060A 100mV/A High Frequency Flexible Current Probe 30MHz Bandwidth , 0.06KA Peak Current For Power Bus Monitoring

Shenzhen Knowhow Technology Co.,limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap HCTS0060A 100mV/A High Frequency Flexible Current Probe 30MHz Bandwidth , 0.06KA Peak Current For Power Bus Monitoring from wholesalers
     
    Buy cheap HCTS0060A 100mV/A High Frequency Flexible Current Probe 30MHz Bandwidth , 0.06KA Peak Current For Power Bus Monitoring from wholesalers
    • Buy cheap HCTS0060A 100mV/A High Frequency Flexible Current Probe 30MHz Bandwidth , 0.06KA Peak Current For Power Bus Monitoring from wholesalers
    • Buy cheap HCTS0060A 100mV/A High Frequency Flexible Current Probe 30MHz Bandwidth , 0.06KA Peak Current For Power Bus Monitoring from wholesalers
    • Buy cheap HCTS0060A 100mV/A High Frequency Flexible Current Probe 30MHz Bandwidth , 0.06KA Peak Current For Power Bus Monitoring from wholesalers

    HCTS0060A 100mV/A High Frequency Flexible Current Probe 30MHz Bandwidth , 0.06KA Peak Current For Power Bus Monitoring

    Ask Lasest Price
    Brand Name : MEASTEK
    Model Number : HCTS0060A
    Payment Terms : T/T,Western Union,MoneyGram
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    HCTS0060A 100mV/A High Frequency Flexible Current Probe 30MHz Bandwidth , 0.06KA Peak Current For Power Bus Monitoring

    HCTS0060A 100mV/A High Frequency Flexible Current Probe 30MHz Bandwidth , 0.06KA Peak Current For Power Bus Monitoring


    Precise current measurement

    Sensitivity 100mV/A, typical accuracy 2%, can accurately measure current, effectively measure the harmonic composition in the current, and provide reliable data for circuit analysis.


    Excellent high-frequency response

    The high-frequency bandwidth of 30MHz can accurately detect high-frequency sinusoidal current waveforms, and has obvious advantages in high-frequency scenarios such as semiconductor switch current measurement.


    Adapt to small package devices

    The small and soft induction loop has an outer diameter of 1.6mm (1.7mm Max) and a withstand voltage of 1KVpk, which is an ideal choice for current measurement of small package devices, such as IGBT and MOSFET pin current measurement.


    Low insertion loss

    The insertion loss is extremely low, only a few picohenries, and there is almost no interference to the circuit under test. The standard BNC interface is convenient for connecting various measurement devices.


    Flexible power supply and operation

    It adopts USB 5V power supply and is simple to operate. Follow safety precautions when using, such as checking the probe ring, staying away from interference sources, etc., to ensure accurate measurement.


    Specifications

    ModelHCTS0060A
    Sensitivity (mV/A)100
    PeakCurrent (KA)0.06

    dI/dt(KA/μs)

    4
    Maximum noise (mV Vpp)20
    Attenuation characteristics(%/ms)65
    Low frequency bandwidth -3dB(Hz)67
    High frequency bandwidth -3dB(MHz)30
    Typical accuracy

    2%

    Insulation voltage value

    1KV


    HCT(S)XXXXA Series Other Technical Parameters

    Maximum output voltage

    6Vpk

    Terminal load

    ≥100kΩ

    Power supply modeUSB 5V (standard adapter)
    Operating temperature rangeIntegrator

    0℃ - 50℃

    Probe ring

    0℃ - 100℃

    Storage temperature range

    -40℃~80℃


    Product Description

    HCTS0060A 100mV/A High Frequency Flexible Current Probe 30MHz Bandwidth , 0.06KA Peak Current For Power Bus Monitoring

    (Take HCTS0120A as an example)


    1) Input interface: current probe test signal input terminal.
    2) Output interface: current probe integrator signal output terminal.
    3) USB 5V power supply interface: standard USB (type B) interface. (USB power supply cable and power adapter are standard)

    4) Test connection diagram.

    HCTS0060A 100mV/A High Frequency Flexible Current Probe 30MHz Bandwidth , 0.06KA Peak Current For Power Bus Monitoring


    Mechanical specifications

    ModelHCTSXXXXA
    Typical value of flexible probe circumference (customizable)

    80mm

    Typical value of induction ring body diameter

    1.6mm

    Typical value of flexible probe diameter (customizable)

    25mm

    Induction loop connection cable length1 M (customizable)
    BNC connection cable length1 M or 2 M, 1 M is Standard

    Integrator body dimensions

    (including BN port dimensions)

    About 110(L)*47(W)*30(H)mm
    USB cable (AM-BM)About 1.8m
    USB output adapterAbout 59mm*30mm*20mm
    Probe weightAbout 150g
    Box weight (including probe)About 960g


    Care And Maintenance

    1) Keep the probe clean and dry.
    2) If cleaning is required, wipe with a soft dry cloth. Do not use chemical cleaning agents.
    3) When the probe is not in use, please put it in the packaging provided and place it in a cool, clean and dry place.
    4) When transporting the probe, be sure to put it in the packaging provided by our company to prevent shock.
    5) Do not pull the input and output lines hard to avoid excessive twisting, bending or knotting.


    Packing List

    NameQuantity
    Current probe integrator1 piece
    Current probe flexible induction coil1 piece
    USB output adapter (5V/1A)1 piece
    USB power cable1 piece
    BNC output cable1 piece
    Electronic manual1 serving