Sign In | Join Free | My himfr.com
Home > Electronics Test Instruments >

MEASTEK HCTM3000A High Frequency Flexible High Current Probe 15MHz High Frequency For Electric Vehicle Charging Pile Current Detection

Shenzhen Knowhow Technology Co.,limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap MEASTEK HCTM3000A High Frequency Flexible High Current Probe 15MHz High Frequency For Electric Vehicle Charging Pile Current Detection from wholesalers
     
    Buy cheap MEASTEK HCTM3000A High Frequency Flexible High Current Probe 15MHz High Frequency For Electric Vehicle Charging Pile Current Detection from wholesalers
    • Buy cheap MEASTEK HCTM3000A High Frequency Flexible High Current Probe 15MHz High Frequency For Electric Vehicle Charging Pile Current Detection from wholesalers

    MEASTEK HCTM3000A High Frequency Flexible High Current Probe 15MHz High Frequency For Electric Vehicle Charging Pile Current Detection

    Ask Lasest Price
    Brand Name : MEASTEK
    Model Number : HCTM3000A
    Payment Terms : T/T,Western Union,MoneyGram
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    MEASTEK HCTM3000A High Frequency Flexible High Current Probe 15MHz High Frequency For Electric Vehicle Charging Pile Current Detection

    MEASTEK HCTM3000A High Frequency Flexible High Current Probe 15MHz High Frequency For Electric Vehicle Charging Pile Current Detection


    1. Low sensitivity for large current measurement

    The sensitivity is 2mV/A, which is specially designed for measuring large currents. It can maintain stable measurement performance at a peak current of 3.0KA, and is suitable for monitoring large current scenarios such as large power equipment and high-voltage transmission lines. ​


    2. Minimum noise interference

    The maximum noise is 8mV Vpp, which effectively reduces the noise interference during the measurement process and provides you with pure and accurate current measurement data. In a complex electromagnetic environment, the real current signal of the device can also be clearly obtained to help you make accurate judgments. ​


    3. Stable attenuation characteristics

    The attenuation characteristics are 0.4%/ms, which ensures the stability and accuracy of the measurement data. In the long-term measurement process, it can effectively reduce the error caused by signal attenuation and provide you with reliable long-term monitoring data. ​


    4. Reliable high-frequency measurement capability

    The high-frequency bandwidth -3dB is 15MHz. For some large current signals with high-frequency components, the current probe in complex wiring environments, such as high-frequency currents in power electronic devices, can accurately measure and meet your needs for complex current signal analysis.​


    5. Convenient installation and operation

    The convenient installation structure and operation method are designed, so that installation and measurement can be easily completed even in places with limited space and inconvenient operation. The simple and easy-to-understand operation interface allows you to use it without complicated training, improving work efficiency.


    Specifications

    ModelHCTM3000A
    Sensitivity (mV/A)2
    PeakCurrent (KA)3.0

    dI/dt(KA/μs)

    25
    Maximum noise (mV Vpp)8
    Attenuation characteristics(%/ms)0.4
    Low frequency bandwidth -3dB(Hz)0.5
    High frequency bandwidth -3dB(MHz)15
    Typical accuracy

    2%

    Insulation voltage value

    2KV


    HCT(S)XXXXA Series Other Technical Parameters

    Maximum output voltage

    6Vpk

    Terminal load

    ≥100kΩ

    Power supply modeUSB 5V (standard adapter)
    Operating temperature rangeIntegrator

    0℃ - 50℃

    Probe ring

    0℃ - 100℃

    Storage temperature range

    -40℃~80℃


    Product Description

    MEASTEK HCTM3000A High Frequency Flexible High Current Probe 15MHz High Frequency For Electric Vehicle Charging Pile Current Detection

    (Take HCTS0120A as an example)


    1) Input interface: current probe test signal input terminal.
    2) Output interface: current probe integrator signal output terminal.
    3) USB 5V power supply interface: standard USB (type B) interface. (USB power supply cable and power adapter are standard)

    4) Test connection diagram.

    MEASTEK HCTM3000A High Frequency Flexible High Current Probe 15MHz High Frequency For Electric Vehicle Charging Pile Current Detection


    Mechanical specifications

    ModelHCTSXXXXA
    Typical value of flexible probe circumference (customizable)

    80mm

    Typical value of induction ring body diameter

    1.6mm

    Typical value of flexible probe diameter (customizable)

    25mm

    Induction loop connection cable length1 M (customizable)
    BNC connection cable length1 M or 2 M, 1 M is Standard

    Integrator body dimensions

    (including BN port dimensions)

    About 110(L)*47(W)*30(H)mm
    USB cable (AM-BM)About 1.8m
    USB output adapterAbout 59mm*30mm*20mm
    Probe weightAbout 150g
    Box weight (including probe)About 960g


    Care And Maintenance

    1) Keep the probe clean and dry.
    2) If cleaning is required, wipe with a soft dry cloth. Do not use chemical cleaning agents.
    3) When the probe is not in use, please put it in the packaging provided and place it in a cool, clean and dry place.
    4) When transporting the probe, be sure to put it in the packaging provided by our company to prevent shock.
    5) Do not pull the input and output lines hard to avoid excessive twisting, bending or knotting.


    Packing List

    NameQuantity
    Current probe integrator1 piece
    Current probe flexible induction coil1 piece
    USB output adapter (5V/1A)1 piece
    USB power cable1 piece
    BNC output cable1 piece
    Electronic manual1 serving


    Quality MEASTEK HCTM3000A High Frequency Flexible High Current Probe 15MHz High Frequency For Electric Vehicle Charging Pile Current Detection for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Knowhow Technology Co.,limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)