UHCT012KA 12kA Lightning Current Probe 2%/ms Low Attenuation | Extreme Environment Adaptation Power System Dedicated

Shenzhen Knowhow Technology Co.,limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap UHCT012KA 12kA Lightning Current Probe 2%/ms Low Attenuation | Extreme Environment Adaptation Power System Dedicated from wholesalers
     
    Buy cheap UHCT012KA 12kA Lightning Current Probe 2%/ms Low Attenuation | Extreme Environment Adaptation Power System Dedicated from wholesalers
    • Buy cheap UHCT012KA 12kA Lightning Current Probe 2%/ms Low Attenuation | Extreme Environment Adaptation Power System Dedicated from wholesalers
    • Buy cheap UHCT012KA 12kA Lightning Current Probe 2%/ms Low Attenuation | Extreme Environment Adaptation Power System Dedicated from wholesalers

    UHCT012KA 12kA Lightning Current Probe 2%/ms Low Attenuation | Extreme Environment Adaptation Power System Dedicated

    Ask Lasest Price
    Brand Name : MEASTEK
    Model Number : UHCT012KA
    Payment Terms : T/T,Western Union,MoneyGram
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    UHCT012KA 12kA Lightning Current Probe 2%/ms Low Attenuation | Extreme Environment Adaptation Power System Dedicated

    MEASTEK UHCT012KA 12kA Lightning Current Probe | 2%/ms Low Attenuation | Extreme Environment Adaptation | Shockproof And Moisture-proof Packaging | Dedicated For Power Systems | Customized Sensitivity


    1. Ultra-large capacity design: peak current 12kA, optimized for short-circuit/lightning current detection in power systems.


    2. High-frequency bandwidth 50MHz: supports microsecond transient waveform analysis, such as lightning impulse current.


    3. Low attenuation characteristics 2.0%/ms: minimize signal distortion and ensure data authenticity.


    4. High temperature and corrosion resistance: the probe ring material adapts to extreme environments and extends service life.


    5. Flexible customization service: supports coil circumference and sensitivity customization to meet special scene requirements.


    6. Standard protective packaging: shockproof and moisture-proof design to ensure transportation and storage safety.


    Technical Parameters

    ModelUHCT012KA
    Sensitivity (mV/A)0.5
    Peak current (KA)12.0
    Maximum noise (mV Vp-p)10
    Attenuation characteristics (%/ms)2.0
    Low frequency bandwidth -3dB (Hz)1.3
    Peak di/dt (A/ns)160
    High frequency bandwidth -3dB (MHz)50

    Note: If you need a larger range, please consult the manufacturer. It can be customized according to your requirements.
    Other Technical Parameters

    Accuracy

    2%

    Insulation withstand voltage value

    2KV

    Terminal load

    ≥100kΩ

    Power supply methodUSB 5V (standard adapter)
    Ring circumference100mm (customizable)
    Coil lead length1.0m (customizable)
    Operating temperature rangeIntegrator

    0℃ - 50℃

    Probe ring

    0℃ - 100℃

    Storage temperature range

    -40℃~80℃

    Front end dimensionsAbout 110(L)*45(W)*30(H)mm
    Probe weightIntegrator

    About125g

    Total weight

    About180g


    Product Description


    UHCT012KA 12kA Lightning Current Probe 2%/ms Low Attenuation | Extreme Environment Adaptation Power System Dedicated

    1) Input interface: probe ring input interface.
    2) Output interface: integrator output interface.
    3) USB 5V power supply interface: standard USB (type B) interface, USB power supply cable as standard.
    Probe induction ring body diameter: 3.5mm
    Coil circumference: 100mm


    Care And Maintenance

    *The current transmitter can only be guaranteed to operate safely and trouble-free if it is properly transported, stored, installed, and carefully operated and maintained.
    *Keep the probe clean and dry, and wipe it with a soft dry cloth.
    *When transporting the probe, put it in the standard packaging to prevent shock.
    *Do not force the flexible probe ring and connecting wire to avoid damage due to excessive twisting, bending or knotting.


    Packing List

    Integrator1 piece
    Flexible coil1 piece
    USB output adapter (5V/1A)1 piece
    USB power cable1 piece
    BNC output cable1 piece
    Electronic manual1 serving


    Notes

    1. To ensure measurement accuracy, the measured wire should pass through the center of the probe ring during measurement.
    2. The error is greatest at the junction of the induction rings, and the measured wire should try to avoid this area.
    3. Make sure the probe ring is inserted in place (to the bottom) during measurement, otherwise it will affect the measurement accuracy.
    4. When measuring the measured signal, if there is a strong magnetic field interference source nearby (such as a magnetic field radiation source composed of multiple coils), it should be kept as far away as possible, otherwise it will cause measurement errors.